    Environmental-Friendly Foam Extinguishing Equipmen
    PC Series of Low Expansion Foam Generator
    PCL Series Vertical Low Expansion Foam GeneratorStructure and PrincipleVertical Low Expansion Foam Generator adopts vertical installation of storage tank, which operates with ease-of-use.Vertical foam

    PCL Series Vertical Low Expansion Foam Generator

    Structure and Principle

    Vertical Low Expansion Foam Generator adopts vertical installation of storage tank, which operates with ease-of-use.

    Vertical foam generator comprises inlet flange, foam generator body, buffer tank body and mist outlet flange plate. The foam guide board in the storage tank is identical with that in horizontal foam generator, which can be used in common.

    Vertical foam generator must  be installed in conformity with instructions. The openings on the walls of the storage tank must be operated according to instructions.

    Performance Parameter

     

    Model

    Rated Working Pressure (MPa)

    Mixture Flow Rate (L/S)

    Range of Mixture Inlet Pressure

    Air Foam Flow Rate (L/S)

    Foam Expansion (Times)

    Drainage time

    PCL4

    0.5

    4

    0.5

    20

    ≧5

    ≧2

    PCL8

    8

    40

    PCL16

    16

    80

    PCL24

    24

    120

    Outline Dimension Table of PCL Series Vertical Low Expansion Foam Generator

     

    Model

    H

    H1

    ФA

    B

    Inlet Flange

    Outlet Flange

    dn

    d1

    d0

    n-Фd2

    DN

    D1

    D0

    N-Фd3

    PCL4

    700

    410

    410

    200

    50

    Ф165

    Ф125

    4-Ф18

    65

    Ф165

    Ф130

    4-Ф14

    PCL8

    750

    500

    500

    220

    65

    Ф185

    Ф145

    4-Ф18

    80

    Ф190

    Ф152

    4-Ф18

    PCL16

    800

    550

    550

    260

    80

    Ф200

    Ф160

    8-Ф18

    125

    Ф260

    Ф210

    4-Ф18

    PCL24

    850

    600

    600

    300

    100

    Ф220

    Ф180

    8-Ф18

    150

    Ф240

    Ф290

    4-Ф18

     

     

    Storage tank wall, PCL4/8 outlet flange, Inlet flange, PCL16/24 outlet flange

    1. Buffer tank 2. Outlet pipe flange 3.Foam generator 4.Inlet pipe flange 5.Guide board group 6.Sealed glass

     

    Model

    D

    D1

    d

    H

    H1

    n

    mm


    PC4/PCL4

    80

    130

    14

    180

    90

    4

    PC8/PCL8

    95

    152

    18

    200

    100

    4

    PC16/PCL16

    150

    210

    18

    240

    130

    8

    PC24/PCL24

    180

    240

    18

    280

    150

    8

     

    wps12 

    Tank roof, opening for guide board installation, Storage tank wall, Maximum storage level line

    Diagram of Storage Tank Wall Opening


    CASE Please submit your inquiry information to us at any time. We will contact you as soon as possible.
    Order online Please feel free to submit your inquiry information to us. We will contact you as soon as possible.
    Name :
    Emai :
    Tel :
    Content:
    Pin:
    日产AV自拍,第一自拍国内一区,日韩成人自拍,日韩网红美女主播自拍 (function(){ var bp = document.createElement('script'); var curProtocol = window.location.protocol.split(':')[0]; if (curProtocol === 'https') { bp.src = 'https://zz.bdstatic.com/linksubmit/push.js'; } else { bp.src = 'http://push.zhanzhang.baidu.com/push.js'; } var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(bp, s); })();